Benshaw low voltage soft starters provide mission critical reliability, patented soft start technology and integral digital protection. Open chassis, protected chassis and packaged low voltage soft starters are available.
Chassis Starters
Browse all available products below …
- EMX4i Full Featured Protected Chassis Soft Starter (100HP, 230V / 200HP, 460V STD Duty)$5,937.00Extended Part No: EMX4i-0397B-V5-C1-H Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200- 525 volts AC. Standard Duty: 100HP, 230V / 200HP, 460V - 261A max Heavy Duty: 75HP, 230V / 150HP, 460V - 203A max
- RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 156A max)$6,066.00Extended Part No: RB3-1-S-156A-14C Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology
- EMX4e Cost Optimized Protected Chassis Soft Starter (150HP, 230V / 350HP, 460V)$6,132.00Extended Part No: EMX4e-0550B-V5-C1-H Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. Standard Duty: 350% current for 30 seconds, line voltage 200- 525 volts AC. Simple setup and commissioning, 120v control power required. Standard Duty: 150HP 230V / 350HP 460V
- RB2 Open Chassis Soft Starter with MX2 Technology (240-575V – 240A max)$6,194.00Extended Part No: RB2-1-S-240A-15C Run duty integral bypass, open chassis soft starter with Benshaw MX2 Technology Standard Duty: 100HP, 240V / 200HP, 480V / 250HP, 575V
- EMX4e Cost Optimized Protected Chassis Soft Starter (200HP, 230V / 400HP, 460V)$6,384.00Extended Part No: EMX4e-0580B-V5-C1-H Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. Standard Duty: 350% current for 30 seconds, line voltage 200- 525 volts AC. Simple setup and commissioning, 120v control power required. Standard Duty: 200HP, 230V / 400HP, 460V
- RB2 Open Chassis Soft Starter with MX2 Technology (240-575V – 180A max)$6,507.00Extended Part No: RB2-1-S-180A-15C Run duty integral bypass, open chassis soft starter with Benshaw MX2 Technology Standard Duty: 75HP, 240V / 150HP, 480V / 200HP, 575V Heavy Duty: 50HP, 240V / 100HP, 480V / 125HP, 575V Severe Duty: 40HP, 240V / 75HP, 480V / 100HP, 575V
- RB2 Open Chassis Soft Starter with MX2 Technology (240-575V – 302A max)$6,816.00Extended Part No: RB2-1-S-302A-15C Run duty integral bypass, open chassis soft starter with Benshaw MX2 Technology Standard Duty: 125HP, 240V / 250HP, 480V / 300HP, 575V
- EMX4i Full Featured Protected Chassis Soft Starter (150HP, 230V / 300HP, 460V STD Duty)$6,893.00Extended Part No: EMX4i-0410B-V5-C1-H Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200 - 525 volts AC. Standard Duty: 150HP, 230V / 300HP, 460V - 377A max Heavy Duty: 100HP, 230V / 250HP, 460V - 302A max
- RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 240A max)$7,156.00Extended Part No: RB3-1-S-240A-15C Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology Standard Duty: 100HP, 240V / 200HP, 480V / 250HP, 575V
Packaged Starters
Browse all available products below …
- RX4E Combination Soft Starter with MX4 Technology (75HP, 480V Heavy Duty – 96A max – NEMA 3R) 65k$9,463.00Extended Part No: RX4E-075-480-3RKP-HB Low voltage soft starter with across the line bypass, 225A circuit breaker, NEMA 3R enclosure Heavy Duty: 75HP 480V
- RX4E Combination Soft Starter with MX4 Technology (100HP, 480V Heavy Duty – 124A max – NEMA 12) 65K$9,661.00Extended Part No: RX4E-100-480-12KP-HB Low voltage soft starter with across the line bypass, 225A circuit breaker, NEMA 12 enclosure Heavy Duty: 100HP 480V
- RX4E Combination Soft Starter with MX4 Technology (125HP, 480V Heavy Duty – 156A max – NEMA 12) 65k$9,722.00Extended Part No: RX4E-125-480-12KP-HB Low voltage soft starter with across the line bypass, 225A circuit breaker, NEMA 12 enclosure Heavy Duty: 125HP 480V
- RX3E Combination Soft Starter with MX3 Technology (50HP, 480V Severe Duty – 65A max – NEMA 3R)$9,784.00Extended Part No: RX3E-050-480-3RKP Low voltage soft starter with an across the line bypass, 100A circuit breaker, NEMA 3R enclosure Heavy Duty: 50HP 480V
- RX3E Combination Soft Starter with MX3 Technology (75HP, 480V Severe Duty – 96A max – NEMA 12)$9,796.00Extended Part No: RX3E-075-480-12KP Low voltage soft starter with an across the line bypass, 225A circuit breaker, NEMA 12 enclosure Heavy Duty: 75HP 480V
- RX2E Combination Soft Starter with MX2 Technology (75HP, 480V Severe Duty – NEMA 3R)$9,899.00Extended Part No: RX2E-075-480-3RKP Low voltage soft starter with an across the line bypass, 225A circuit breaker, NEMA 3R enclosure Heavy Duty: 75HP 480V
- RX4E Combination Soft Starter with MX4 Technology (150HP, 480V Heavy Duty – 180A max – NEMA 12) 65k$10,081.00Extended Part No: RX4E-150-480-12KP-HB Low voltage soft starter with across the line bypass, 300A circuit breaker, NEMA 12 enclosure Heavy Duty: 150HP 480V
- MX4PB Combination Soft Starter with EMX4i Technology (75HP, 240V Heavy Duty – 192A max) 65K$10,504.00Extended Part No: MX4PB-HD-075-2-4-HB Combination soft starter with run duty integral bypass, 350A circuit breaker and NEMA4 enclosure. Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor Heavy Duty: 75HP 240V
- MX4PB Combination Soft Starter with EMX4i Technology (150HP, 460V Heavy Duty – 180A max) 65K$10,504.00Extended Part No: MX4PB-HD-150-4-4-HB Combination soft starter with run duty integral bypass, 300A circuit breaker and NEMA4 enclosure. Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor Heavy Duty: 150HP 480V
Need help finding the LV soft starter(s) you need?