• 0Shopping Cart
Troy Industrial Solutions
  • Home
  • About Us
  • Services
    • Overview
  • Motor Controls & Drives
    • Control Components
      • Overview
      • Circuit Breakers
      • Contactors & Overload Relays
      • Line & Load Reactors
      • Pilot Devices
    • LV Motor Controls & Drives
      • Overview
      • LV Soft Starters
      • LV Full Voltage Controls
      • LV Variable Frequency Drives
      • Multi-Motor Control Panels
      • Synchronous Controls
    • MV Motor Controls & Drives
      • Overview
      • MV Soft Starters
      • MV Full Voltage Starters
      • Modular Medium Voltage VFDs
      • Multi-Purpose Drives
      • MCCs
    • And More
      • Parts/Accessories
  • Webstore
    • Visit Shop
    • Register/Edit Account
    • View My Shopping Cart
    • Log In
  • Contact Us
  • Search
  • Menu Menu
  • Home
  • Webstore
    • Circuit Breakers
    • Contactors and Relays
    • Low Voltage Soft Starters
    • LV Variable Frequency Drives
    • Medium Voltage Controls
    • Line and Load Reactors
    • Full Voltage Starters
    • Pilot Devices
    • Accessories
  • Login/Register
  • Terms of Use
  • Contact Us
  • Privacy
  • Low Voltage Chassis Soft Starters

    Industrial Motor Controls and Drives Webstore

Open Chassis Starters

  • RB Series Open Chassis Soft Starters
    RB2 Open Chassis Soft Starter with MX2 Technology (240-575V – 302A max)
    $6,816.00
    Extended Part No: RB2-1-S-302A-15C Run duty integral bypass, open chassis soft starter with Benshaw MX2 Technology Standard Duty: 125HP, 240V / 250HP, 480V / 300HP, 575V
  • RB Series Open Chassis Soft Starters
    RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 240A max)
    $7,156.00
    Extended Part No: RB3-1-S-240A-15C Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology Standard Duty: 100HP, 240V / 200HP, 480V / 250HP, 575V
  • RB Series Open Chassis Soft Starters
    RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 180A max)
    $7,436.00
    Extended Part No: RB3-1-S-180A-15C Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology Standard Duty: 75HP, 240V / 150HP, 480V / 200HP, 575V Heavy Duty: 50HP, 240V / 100HP, 480V / 125HP, 575V Severe Duty: 40HP, 240V / 75HP, 480V / 100HP, 575V
  • RB Series Open Chassis Soft Starters
    RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 302A max)
    $7,800.00
    Extended Part No: RB3-1-S-302A-15C Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology Standard Duty: 125HP, 240V / 250HP, 480V / 300HP, 575V
  • RB Series Open Chassis Soft Starters
    RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 361A max)
    $7,800.00
    Extended Part No: RB3-1-S-361A-16C Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology Standard Duty: 150HP, 240V / 300HP, 480V / 400HP, 575V Heavy Duty: 100HP, 240V / 200HP, 480V / 250HP, 575V Severe Duty: 75HP, 240V / 150HP, 480V / 200HP, 575V
  • RB Series Open Chassis Soft Starters
    RB2 Open Chassis Soft Starter with MX2 Technology (240-575V – 361A max)
    $7,986.00
    Extended Part No: RB2-1-S-361A-16C Run duty integral bypass, open chassis soft starter with Benshaw MX2 Technology Standard Duty: 150HP, 240V / 300HP, 480V / 400HP, 575V Heavy Duty: 100HP, 240V / 200HP, 480V / 250HP, 575V Severe Duty: 75HP, 240V / 150HP, 480V / 200HP, 575V
  • RB Series Open Chassis Soft Starters
    RB2 Open Chassis Soft Starter with MX2 Technology (240-575V – 414A max)
    $8,736.00
    Extended Part No: RB2-1-S-414A-17C Run duty integral bypass, open chassis soft starter with Benshaw MX2 Technology Standard Duty: 175HP, 240V / 350HP, 480V / 450HP, 575V Heavy Duty: 150HP, 240V / 300HP, 480V / 400HP, 575V Severe Duty: 125HP, 240V / 250HP, 480V / 300HP, 575V
  • RB Series Open Chassis Soft Starters
    RB3 Open Chassis Soft Starter with MX3 Technology (240-575V – 414A max)
    $9,474.00
    Extended Part No: RB3-1-S-414A-17C Run duty integral bypass, open chassis soft starter with Benshaw MX3 technology Standard Duty: 175HP, 240V / 350HP, 480V / 450HP, 575V Heavy Duty: 150HP, 240V / 300HP, 480V / 400HP, 575V Severe Duty: 125HP, 240V / 250HP, 480V / 300HP, 575V
  • RB Series Open Chassis Soft Starters
    RB2 Open Chassis Soft Starter with MX2 Technology (240-575V – 477A max)
    $9,541.00
    Extended Part No: RB2-1-S-477A-17C Run duty integral bypass, open chassis soft starter with Benshaw MX2 Technology Standard Duty: 200HP, 240V / 400HP, 480V / 500HP, 575V
Page 3 of 41234

More …

Protected Chassis Starters

  • CSXi Series Soft Starters
    CSXi Compact Protected Chassis Soft Starter (30HP, 230V / 75HP, 460V / 100HP, 575V)
    $1,943.00
    Extended Part No: CSXi-055-V6-C1 Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. 400% current for 6 seconds / Max amps @ 50 degrees C: 100A. Simple setup and commissioning. 120v control power required. Standard Duty: 75HP,460V / 100HP,575V
  • EMX4i Series Protected Chassis Soft Starters
    EMX4e Cost Optimized Protected Chassis Soft Starter (30HP, 230V / 60HP, 460V)
    $2,099.00
    Extended Part No: EMX4e-0115B-V5-C1-H Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. Standard Duty: 350% current for 30 seconds, line voltage 200- 525 volts AC. Simple setup and commissioning, 120v control power required. Standard Duty: 30HP, 230V / 60HP, 460V
  • EMX4i Series Protected Chassis Soft Starters
    EMX4i Full Featured Protected Chassis Soft Starter (25HP, 230V / 60HP, 460V STD Duty)
    $2,207.00
    Extended Part No: EMX4i-0105B-V5-C1-H Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200- 525 volts AC. Standard Duty: 25HP, 230V / 60HP, 460V Heavy Duty: 15HP, 230V / 40HP, 460V - 52A max
  • EMX4i Series Protected Chassis Soft Starters
    EMX4e Cost Optimized Protected Chassis Soft Starter (30HP, 230V / 75HP, 460V)
    $2,331.00
    Extended Part No: EMX4e-0135B-V5-C1-H Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. Standard Duty: 350% current for 30 seconds, line voltage 200- 525 volts AC. Simple setup and commissioning, 120v control power required. Standard Duty: 30HP, 230V / 75HP, 460V
  • CSXi Series Soft Starters
    CSXi Compact Protected Chassis Soft Starter (50HP, 230V / 100HP, 460V / 125HP, 575V)
    $2,442.00
    Extended Part No: CSXi-075-V6-C1 Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. 400% current for 6 seconds / Max amps @ 50 degrees C: 133A. Simple setup and commissioning. 120v control power required. Standard Duty: 50HP,230V / 100HP,460V / 125HP,575V
  • EMX4i Series Protected Chassis Soft Starters
    EMX4i Full Featured Protected Chassis Soft Starter (30HP, 230V / 60HP, 460V STD Duty)
    $2,469.00
    Extended Part No: EMX4i-0115B-V5-C1-H Advanced, protected chassis solid state soft starter with built-in bypass, 350% current for 30 seconds (standard duty), 450% for 30 seconds (heavy duty), line voltage 200- 525 volts AC. Standard Duty: 30HP, 230V / 60HP, 460V Heavy Duty: 20HP, 230V / 50HP, 460V - 65A max
  • EMX4i Series Protected Chassis Soft Starters
    EMX4e Cost Optimized Protected Chassis Soft Starter (40HP, 230V / 100HP, 460V)
    $2,632.00
    Extended Part No: EMX4e-0184B-V5-C1-H Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. Standard Duty: 350% current for 30 seconds, line voltage 200- 525 volts AC. Simple setup and commissioning, 120v control power required. Standard Duty: 40HP, 230V / 100HP, 460V
  • CSXi Series Soft Starters
    CSXi Compact Protected Chassis Soft Starter (60HP, 230V / 125HP, 460V / 150HP, 575V)
    $2,713.00
    Extended Part No: CSXi-090-V6-C1 Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. 400% current for 6 seconds / Max amps @ 50 degrees C: 157A. Simple setup and commissioning. 120v control power required. Standard Duty: 60HP,230V / 125HP,460V / 150HP,575V
  • EMX4i Series Protected Chassis Soft Starters
    EMX4e Cost Optimized Protected Chassis Soft Starter (50HP, 230V / 100HP, 460V)
    $2,746.00
    Extended Part No: EMX4e-0200B-V5-C1-H Low voltage soft starter with a built-in bypass, ideal for pump and fan applications. Standard Duty: 350% current for 30 seconds, line voltage 200- 525 volts AC. Simple setup and commissioning, 120v control power required. Standard Duty: 50HP, 230V / 100HP, 460V
Page 3 of 7‹12345›»

More …

Need help finding the chassis starter(s) you need?

Contact Us
  • Chassis Starters
    • Open Chassis
    • Protected Chassis
  • Packaged Soft Starters
    • Across-the-Line Bypass
    • Run Duty Integral Bypass
    • Pump Panels
  • Parts/Accessories
© Copyright 2025 Troy Industrial Solutions.
  • Facebook
  • Youtube
  • LinkedIn
Scroll to top